630-735-3500

T280-wp-1200x1200.webp

Automatic Suction Valve

SKU#: T280

Typically ships in 2 weeks

Ships via Standard Ground

This 6” F X 6” M NST suction inlet valve is designed to operate as an automatic flow control valve.

Price:$2,989.95

Looking for a quote? Simply add your items to the cart and choose Request for Quote during checkout.

Enter a value between 1 and 100000000 in increments of 1.

Earn Darley Dollars with this purchase

Description

Automatic suction valve designed to adjust for flow, maintaining the prime in your hard suction hose during drafting operations. It can also be used in hydrant operations when filling up your truck, acting as a check valve to eliminate the need to close the valve after fill-up when in the automatic position. This valve is compact, lightweight, durable, and easy to maintain/service. The PC3 comes with a 3-year manufacturer's warranty that is superior to its competition.


Usage Instructions

The PC3 Model Pre-Con is used primarily in firefighting operations. During drafting operations, it keeps the prime in your hard suction hose, ensuring a continuous flow of water. In hydrant operations, it acts as a check valve, automatically adjusting to maintain flow and eliminating the need to manually close the valve after filling up your truck.


Installation Instructions

  • Tools Required
    • Wrenches appropriate for the valve size
    • Lubricant suitable for aluminum components
    • Clean cloths or rags

Steps

  • Preparation
    • Ensure the valve and all connecting hoses are clean and free from debris.
    • Inspect the valve for any signs of damage or wear.
  • Positioning
    • Place the PC3 Model Pre-Con valve in the desired location on your hard suction hose or hydrant connection.
    • Ensure the valve is oriented correctly, with the flow direction matching the intended water flow.
  • Connecting
    • Attach the valve to the hose or hydrant using the appropriate wrench.
    • Tighten the connections securely to prevent leaks. Avoid over-tightening to prevent damage to the threads.
  • Lubrication
    • Apply a suitable lubricant to the moving parts of the valve to ensure smooth operation.
    • Wipe off any excess lubricant with a clean cloth.
  • Testing
    • Once installed, test the valve by initiating a flow of water.
    • Check for any leaks and ensure the valve is operating correctly, maintaining the prime in the suction hose or acting as a check valve during hydrant operations.
  • Final Inspection
    • Perform a final inspection to ensure all connections are secure and the valve is functioning as expected.
    • Make any necessary adjustments.


Maintenance Tips

  • Regular Inspection: Check for any signs of wear or damage.
  • Cleaning: Ensure the valve is clean and free from debris.
  • Lubrication: Apply appropriate lubricants to moving parts to ensure smooth operation.
  • Service: Follow the manufacturer's guidelines for servicing and maintenance.

Specifications

  • Material: A356 Aluminum, heat treated to a T-6 temper
  • Finish: Mil-Spec High Solids, VOC Compliant Epoxy polyamide primer; High solids aliphatic two-component polyurethane coating
  • Flow Range: Up to 1800 GPM
  • Sizes: 6” NH
  • Color: Red
  • Shipping Weight: 38 lbs
  • Model: PC3-6.0FS-6.0M