My Cart

HazMat Suit DuraChem® 200

$1,368.95 Select item options to view correct pricing.

DuraChem 200 Multi-Piece Configuration Certified to NFPA 1992 and NFPA 2112.

Options: Navy or Hi-Vis Yellow


HazMat Suit DuraChem 200 Yellow
HazMat Suit DuraChem 200 Yellow HazMat Suit DuraChem 200 Yellow Angle HazMat Suit DuraChem 200 Navy HazMat Suit DuraChem 200 Navy HazMat Suit DuraChem 200 Navy Pocket HazMat Suit DuraChem 200 Reflective at Night HazMat Suit DuraChem 200 In Use Train HazMat Suit DuraChem 200 Truck HazMat Suit DuraChem 200 Closeup HazMat Suit DuraChem 200 Velcro Boot HazMat Suit DuraChem 200 Zipper HazMat Suit DuraChem 200 Velcro Closeup

DuraChem 200 is multi-purpose, high-visibility FR apparel with added protection against Chemical, Biological, Arc Flash, Steam and Hot Water, and Molten Metal Splash hazards. Available as a coverall or multi-piece configuration, it offers breathable, launderable protection for a wide range of applications for daytime or nighttime work. Certified to or compliant with seven key industry safety standards, it helps simplify PPE selection and inventory with a multi-hazard apparel solution. From industrial applications to emergency response, DuraChem 200 is a proven workhorse with the data to back it up.

 

Features & Benefits

  • DuraChem 200 is the first and only breathable protective apparel certified to or compliant with seven key industry safety standards
  • Attachable hood on jacket with secure hook-and-loop closure
  • Adjustment straps at ankles and wrists, plus other unique design features
  • Launderable Hi-Vis FR protection, plus Chemical, Thermal, Arc Flash, Steam and Hot Water, and Molten Metal Splash protection
  • Breathability reduces heat stress and improves worker comfort
  • 24/7 facility-wide protection for day or night work applications
  • Multi-Purpose garment with flexible hood options simplifies PPE selection and inventory

Specificiations

  • Flame Resistant – NFPA 2112 & ASTM F2733
  • Chemical – NFPA 1992
  • Biological – ASTM F1671 blood and viral test
  • Hi-Vis – ANSI/ISEA 107 Type P, Class 3, plus compliant with OSHA Roadside Emergency Response requirements; does not apply to Navy fabric
  • Arc Flash – NFPA 70E & ASTM F1891
  • Molten Metal Splash – ASTM F955
  • Tested Against Steam and Hot Water – University of Alberta (CAN/CSGB 155.20)

Contents

  • Jacket
  • Bib Overall
  • Attachable Hood
  • Glove Cone Inserts

Thermal and Burn Testing

TEST METHOD RESULT
Heat Thermal Performance (HTP)
ASTM F2700
Spaced: 20.2 cal/cm²
Contact: 14.3 cal/cm²
Flame Resistance
ASTM D6413
Char length: 1.06 in
Afterflame: 0.0 sec
Thermal Protective Performance (TPP)
ISO 17492
13.9 cal/cm²
Shrinkage/Heat Resistance
ASTM F2894
8.0 %, 6.0%
WARP, WEFT
Manikin Body Burn (Pyroman)
ASTM F1930
Exposed Head, min - 6.56%
6.56%
predicted body burn
Heat Transfer - Molten Substances
ASTM F955
Aluminum @ 1400 F: 19.8sec to 2⁰ burn
34.6⁰C increase
Iron @ 2800 F: no burn
11.7⁰C increase
Sulfur @ 302 F: no burn
9.5⁰C increase
Electric Arc Rating
ASTM F1959
APTV = 13 cal/cm²
Steam 302˚F @ 30 psi @ 2.4”
University of Alberta (CAN/CSGB 155.20)
6.8 Seconds to 2nd Degree Burn
19.8 Seconds to 3rd Degree Burn
Hot Water (185˚F @ 6L/min) @ 2.0”
University of Alberta (CAN/CSGB 155.20)
No Burn

 

Comfort Testing

TEST METHOD RESULT
Total Heat Loss
ASTM F1868 Procedure C
492.9 W/m²
Evaporative Resistance
ISO 11092 7.4
13.955 Pa-m²/W
Cold Temperature Performance
ASTM D747
0.009 in/lb
Water Vapor Transmission
ASTM E96
3158 g/m²-24hr

 

Splash Chemical Testing*

CHEMICAL PENETRATION ASTM F903, PROCEDURE C HOLDOUT TIME IN MINUTES
Acetone >60
Acrylonitrile >60
Butyl Acetate >60
Dimethyl Formamide >60
Formic Acid (85%) >60
Fuel H >60
Hydrochloric Acid (37%) >60
Isopropyl Alcohol >60
JP8 >60
Methanol >60
Methyl Isobutyl Ketone >60
Nitrobenzene >60
Phenol (90%) >60
Sodium Hydroxide (50%) >60
Sodium Hypochlorite (10%) >60
Sulfuric Acid (93.1%) >60
Tetrachloroethylene >60
Toluene >60

 

Biohazard Testing - Fabric & Seams

TEST METHOD RESULTS
ASTM F1671 (blood & viral penetration) Pass

 

*Chemical penetration testing was conducted in accordance with ASTM F 903 Procedure C. Note: These tests were performed in accordance with ASTM standards by independent laboratories. This data is derived from tests performed on material samples only, not finished garments.

Kappler

Kappler

View more by Kappler

Kappler on the label gives you the confidence that you're well covered. For more than 40 years Kappler has defined the protective apparel industry with patented fabrics, innovative seaming technology and unique garment designs.

Technical Data
Manufacturer Kappler
UNSPSC 46181509